Choose your region, country and preferred language, then select your application scenario.
Continent
Country / Region
Language
Please select a continent and country to continue.
Application Scenario
Commercial & Industrial
Battery storage for commercial and industrial sites. Peak shaving, demand response, backup power and off-grid capability.
Grid-connected BESS
Best for:Factories, shopping centres, office buildings and industrial facilities connected to the grid.
Reduce peak demand charges by discharging during high-tariff periods
Provide backup or off-grid power during grid outages
AC-coupled — compatible with existing solar installations with their own inverter
DC-coupled Hybrid option available if installing new solar PV without a separate inverter
Utility
Grid-scale storage for frequency regulation, arbitrage and large-scale renewable integration.
Utility Scale BESS
Best for:Utilities, grid operators, IPPs and large renewable energy project developers.
Frequency regulation and ancillary services for grid stability
Energy arbitrage — charge at low-price periods, discharge at peak
Firming capacity for wind and solar farms
Scalable via AC-side parallel connection
Microgrid
Multi-source microgrid integrating solar PV, battery storage and diesel generator for full energy independence.
Microgrid + PV + Diesel
Best for:Remote sites, islands, mining operations, telecoms towers and communities without reliable grid access.
Combine solar PV, BESS and diesel generator under one control system
Dramatically reduce diesel fuel consumption and operating costs
Can operate fully off-grid or as a grid-backup system
Teplore provides full system integration and controls engineering
Please select an application to continue.
System
System Configuration
Select AC power output first. Compatible DC capacities appear automatically. Duration ≥ 2h required (0.5C battery). i
Solar PV Configuration
Do you have solar PV without a dedicated inverter?
Select Yes if you are installing new solar panels that need a Hybrid PCS (DC-coupled).
Select No if you have no solar, or if your solar already has its own inverter (AC-coupled).
Cooling
Select cabinet cooling type
Air cooled — Tensorpack T series. Liquid cooled — Tensorpack L series with higher energy density per cabinet.
Product Type
Select System Format
Grid Connection Voltage
Select AC Voltage First
AC Power Output
PCS Power
Max. PV Input
— kW
Recommended maximum solar PV array size for this PCS
Battery Capacity
Battery Capacity per Unit i
Select AC power first, then choose a compatible DC capacity.
Greyed options have Duration < 2h and are not compatible with the selected AC power.
Battery Brand
Select Battery Cell Manufacturer
Total System Specification
—
Number of Systems
How many complete systems (units) do you need?
Each unit = 1 × AC inverter/PCS. For double-DC configurations (434/482/530 kWh), each unit contains 2 × DC battery cabinets. Max 100 units.
Please select both AC power and DC capacity to continue.
Controls
EMS, Controls & Site Information
Configure your energy management system and provide site information where applicable.
Microgrid Site Information
Existing Site Infrastructure
Tell us about your existing site infrastructure. This helps Teplore design the right microgrid control strategy.
Grid Connection
Is the site connected to the utility grid?
kVA
Grid Capacity
Diesel Generator
Is there an existing diesel generator at the site?
Generator Capacity
Controller Model (optional)
Solar PV
Is there existing or planned solar PV at the site?
kWp
PV Array Capacity
⚠ Please ensure at least one additional power source is selected for a functional microgrid. A standalone BESS without grid, generator or PV is not a microgrid configuration.
Load Information
Site Load Profile
Starting Power
Peak power demand during equipment startup (e.g. motor inrush current). Used to size the BESS discharge capacity.
kW
Running Power
Steady-state power consumption during normal operation. Used to calculate daily energy requirements.
kW
Primary Use Case
Select all applicable applications for this project.
Frequency Regulation
Energy Arbitrage
Capacity Firming
Peak Shaving
Black Start Capability
Operating Requirements
Specify the expected operating parameters for this project.
Cycles per Year
Expected number of full charge/discharge cycles annually.
cycles/yr
Depth of Discharge (DoD)
Maximum discharge depth as percentage of total capacity.
%
Operating Mode
Grid-following: PCS follows grid frequency. Grid-forming: PCS sets voltage and frequency.
Communication Protocol
Select preferred communication protocol(s) for EMS integration.
Modbus
IEC 61850
DNP3
+ Other
Teplore PowerView (Optional)
Teplore's own monitoring and control platform. Provides local visualisation, real-time data. Can be used standalone or alongside a third-party EMS. Billed per point of connection.
Third-Party EMS Integration
Do you require integration with a third-party Energy Management System? Select from our pre-integrated partners below, or specify your preferred vendor.
Teplore will confirm integration feasibility and timeline with you.
Customisation
System Customisation
Specify environmental and performance requirements. Standard values are defaults; upgrades are available on request.
Off-grid Operation
Islanding Capability
Off-grid / Islanding
Do you require the system to operate independently from the grid? Off-grid operation is available with BESS only. For systems combining solar PV or diesel generator, please select the Microgrid scenario.
Corrosion & Climate
Anti-Corrosion Rating i
Default: C4 — suitable for most industrial environments. Upgrade to C5 for marine, coastal or heavy industrial sites.
Ambient Temperature Range
Default: −20 to +55°C. Upgrade to −40 to +55°C for extreme climates.
Noise Level i
Default: ≤ 70 dB(A) — suitable for industrial environments. Upgrade to ≤ 60 dB(A) via additional acoustic accessories, suitable for residential areas.
Additional Components
Optional Hardware Add-ons
MV Transformer
Medium voltage transformer for direct MV grid connection.
kVGrid Voltage
Motorized Breaker
Remote-controlled circuit breaker for automated disconnection and protection.
Services
Warranty & Service Options
Select warranty coverage, service requirements and shipping terms.
Warranty
Warranty Period
Warranty Coverage
Default: 5 Years free warranty included. Extended coverage available at additional cost.
Installation & Commissioning
On-Site Services
Installation Service
Teplore provides professional mechanical installation at your project site.
Grid Commissioning
Default: Remote commissioning. Upgrade to on-site engineer for in-person grid connection and testing.
On-Site Engineer(Standard for Utility Scale)
Operations & Maintenance
Annual O&M
Annual O&M Service
Teplore can provide annual on-site O&M. Alternatively, Teplore offers operator training so your team can self-maintain the system.
Shipping & Logistics
Shipping Terms & Container Summary
Incoterms / Shipping Mode
Default: FOB Shanghai. Select your preferred trade term.
FOB Shanghai — Teplore delivers goods to Shanghai port. Buyer arranges and pays for all freight and insurance from there.
Port of Loading: Shanghai, China
Sea Freight Summary
—
🕐 Standard lead time:4–6 weeks from order confirmation
System Summary
—
Total Battery Capacity
—kWh
Total AC Power
—kW
Duration
—h
Main Equipment
Battery Cabinets (DC)
—
AC Cabinets
—
Depth of Discharge
—
Battery Brand
CATL
Cooling
Air cooled
Battery Life Estimate
Switchgear & Protection
ABB / Schneider
MV Transformer
—
Motorized Breaker
—
Controls & EMS
Teplore PowerView
—
EMS Integration
—
SCADA System
—
Services
Warranty
—
Commissioning
—
Installation
—
Annual O&M
—
Anti-Corrosion
—
Temperature Range
—
Logistics
Incoterms
—
Port / Address
—
Lead Time
4–6 weeks
Project Footprint
—
Microgrid Site Information
⚠
Not Included in Scope of Supply
·Site civil works & foundations
·AC & DC power cabling
·Grid connection & metering
·On-site installation labour
·Import duties & local taxes
·Local permits & approvals
These items are the responsibility of the buyer or EPC contractor. Teplore can provide technical guidance upon request.
Contact
Request Your Solution
Submit your details and our sales team will follow up with a tailored proposal.
Contact Information
Your inquiry will be sent to sales@teplore.com
Configuration Summary (attached to inquiry)
—
Please fill in all required fields.
Please accept the privacy policy to continue.
Sales Enquiries
sales@teplore.com
Technical Support
support@teplore.com
General Inquiries
info@teplore.com
✅
Inquiry Sent!
Thank you! Our sales team will contact you within 2 business days with a tailored proposal for your system.